HPE Network Campus Access Professional Architect - HPE7-A11 Exam Practice Test
Question 1
A large multinational financial institution has contracted you to design a new full-stack wired and wireless network for their new 6-story regional office building. The bottom two floors of this facility will be retail space for a large banking branch. The upper floors will be carpeted office space for corporate users, each floor being approximately 100,000 sq ft (9290 sq m). Data centers are all offsite and will be out of scope for this project. The customer is underserved by its existing L2- based network infrastructure and would like to take advantage of modem best practices in the new design. The network should be fully resilient and fault-tolerant, with dynamic segmentation at the edge.
The retail space will include public guest Wi-Fi access. Retail associates will have corporate tablets for customer service, and there will be a mix of wired and wireless devices throughout the retail floors. The corporate users will primarily use wireless for connectivity, but several wired clients, printers, and hard VoIP phones will be in use.
The customer is also planning on renovating the corporate office space in order to take advantage of 'smart office' technology. These improvements will drive blue-dot wayfinding, presence analytics, and other location-based services.
The client has decided that more critical switch stacks supporting Contact Center resources will need to support greater than 600W of CL4 PoE and have redundant power supplies. These stacks will have approximately six members.
What would be the most economical choice switch series to meet these requirements?
The retail space will include public guest Wi-Fi access. Retail associates will have corporate tablets for customer service, and there will be a mix of wired and wireless devices throughout the retail floors. The corporate users will primarily use wireless for connectivity, but several wired clients, printers, and hard VoIP phones will be in use.
The customer is also planning on renovating the corporate office space in order to take advantage of 'smart office' technology. These improvements will drive blue-dot wayfinding, presence analytics, and other location-based services.
The client has decided that more critical switch stacks supporting Contact Center resources will need to support greater than 600W of CL4 PoE and have redundant power supplies. These stacks will have approximately six members.
What would be the most economical choice switch series to meet these requirements?
Correct Answer: A
Explanation: Only visible for Actualtests4sure members. You can sign-up / login (it's free).
Question 2
Your organization is planning to implement HPE Aruba Networking User Experience Insight (UXI) sensors to enhance network visibility and proactive troubleshooting across your enterprise environment. The goal is to continuously monitor user experience, application performance, and network health across wired, wireless, and WAN segments.
Which capabilities accurately describe the features and requirements of HPE Aruba Networking UXI sensors? (Choose two.)
Which capabilities accurately describe the features and requirements of HPE Aruba Networking UXI sensors? (Choose two.)
Correct Answer: A,D
Explanation: Only visible for Actualtests4sure members. You can sign-up / login (it's free).
Question 3
A large multinational financial institution has contracted you to design a new full-stack wired and wireless network for their new 6-story regional office building. The bottom two floors of this facility will be retail space for a large banking branch. The upper floors will be carpeted office space for corporate users, each floor being approximately 100,000 sq ft (9290 sq m). Data centers are all offsite and will be out of scope for this project. The customer is underserved by its existing L2- based network infrastructure and would like to take advantage of modem best practices in the new design. The network should be fully resilient and fault-tolerant, with dynamic segmentation at the edge.
The retail space will include public guest Wi-Fi access. Retail associates will have corporate tablets for customer service, and there will be a mix of wired and wireless devices throughout the retail floors. The corporate users will primarily use wireless for connectivity, but several wired clients, printers, and hard VoIP phones will be in use.
The customer is also planning on renovating the corporate office space in order to take advantage of 'smart office' technology. These improvements will drive blue-dot wayfinding, presence analytics, and other location-based services.
The client decided that they would like to manage two wiring closets as a single stack with a total of 10 switches and a minimum transport speed of 25Gbps over OM4 MM fiber. They would also like to keep the stacking cabling cost to a minimum.
Which stacking components would be required to meet the customer's requirements in the most cost-effective way if the closets were 190 m (620 ft) apart? (Choose two.)
The retail space will include public guest Wi-Fi access. Retail associates will have corporate tablets for customer service, and there will be a mix of wired and wireless devices throughout the retail floors. The corporate users will primarily use wireless for connectivity, but several wired clients, printers, and hard VoIP phones will be in use.
The customer is also planning on renovating the corporate office space in order to take advantage of 'smart office' technology. These improvements will drive blue-dot wayfinding, presence analytics, and other location-based services.
The client decided that they would like to manage two wiring closets as a single stack with a total of 10 switches and a minimum transport speed of 25Gbps over OM4 MM fiber. They would also like to keep the stacking cabling cost to a minimum.
Which stacking components would be required to meet the customer's requirements in the most cost-effective way if the closets were 190 m (620 ft) apart? (Choose two.)
Correct Answer: A,C
Question 4
A global cruise line company needs to refresh its current fleet. They will refresh the 'insides' of the ship to be cost-effective and increase their sustainability. They will replace the complete WLAN/LAN hardware of the ship. In this refresh, the company will not refresh its current security requirements. The CIO also wants to limit the number of unused ports in the switches. Future expansion will always mean a refresh of hardware. They start with the smallest ship with a maximum of 800 guests.
Each ship has a LAN infrastructure consisting of two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins, 100 technical rooms). The Core switches are located in the MDF of the ship and the distribution switches are located in the IDFs of the ship. Each cabin and technical room gets one single access switch.
The cabling structure of the ship will not be refreshed. Each IDF is connected to the MDF by SMF, of which two pairs are available for the interconnect between the core and distribution. The length of SM fiber between MDF and IDF is less than 300 meters (980 ft) and the type used is OS1. Each cabin is connected by a single OM2 pair to the IDF, the maximum length is 60 meters (200 ft). Each technical room is connected by a single OM2 pair to the IDF, with lengths between
100 and 150 meters (320 and 500 ft).
For each cabin/technical room the customer is looking to replace their current fan-less 2530/2540 without changing the requirements, except they need to upgrade the uplink to distribution switch to 10GbE to handle the increased network traffic, and the technical rooms need redundant power.
The WLAN infrastructure will be 1:1 refreshed without new cabling or new AP locations. Their WLAN infrastructure is based on the 200/300 series indoor and outdoor APs running InstantOS (less than 300 APs), the customer has no change in WLAN requirements.
The cruise line company will replace its current Internet connection before the LAN/WLAN refresh. The new Internet connection will provide a 99.8% uptime, which is needed to ensure the paid guest Wi-Fi is always operational. With this new internet connection, the CIO of the cruise line wants to base the design on the ESP architecture from Aruba because Internet connection is guaranteed.
Based on the best practices, what would you recommend as the correct optic type for the connection between the MDF and the IDFs?
Each ship has a LAN infrastructure consisting of two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins, 100 technical rooms). The Core switches are located in the MDF of the ship and the distribution switches are located in the IDFs of the ship. Each cabin and technical room gets one single access switch.
The cabling structure of the ship will not be refreshed. Each IDF is connected to the MDF by SMF, of which two pairs are available for the interconnect between the core and distribution. The length of SM fiber between MDF and IDF is less than 300 meters (980 ft) and the type used is OS1. Each cabin is connected by a single OM2 pair to the IDF, the maximum length is 60 meters (200 ft). Each technical room is connected by a single OM2 pair to the IDF, with lengths between
100 and 150 meters (320 and 500 ft).
For each cabin/technical room the customer is looking to replace their current fan-less 2530/2540 without changing the requirements, except they need to upgrade the uplink to distribution switch to 10GbE to handle the increased network traffic, and the technical rooms need redundant power.
The WLAN infrastructure will be 1:1 refreshed without new cabling or new AP locations. Their WLAN infrastructure is based on the 200/300 series indoor and outdoor APs running InstantOS (less than 300 APs), the customer has no change in WLAN requirements.
The cruise line company will replace its current Internet connection before the LAN/WLAN refresh. The new Internet connection will provide a 99.8% uptime, which is needed to ensure the paid guest Wi-Fi is always operational. With this new internet connection, the CIO of the cruise line wants to base the design on the ESP architecture from Aruba because Internet connection is guaranteed.
Based on the best practices, what would you recommend as the correct optic type for the connection between the MDF and the IDFs?
Correct Answer: C
Explanation: Only visible for Actualtests4sure members. You can sign-up / login (it's free).
Question 5
You are part of a cross-functional team preparing a detailed design proposal for a customer deploying EVPN-VXLAN in a modern campus core and data center fabric. The customer is transitioning from a traditional VLAN-based Layer 2 design to a VXLAN-based overlay architecture to support segmentation scalability, and automation.
As the solution is reviewed, you're asked to contribute by identifying and explaining core technical behaviors and configuration considerations that are critical to the success of EVPN-VXLAN in this environment.
Which statement accurately describe key characteristics of EVPN-VXLAN in modern campus or data center networks? (Choose two.)
As the solution is reviewed, you're asked to contribute by identifying and explaining core technical behaviors and configuration considerations that are critical to the success of EVPN-VXLAN in this environment.
Which statement accurately describe key characteristics of EVPN-VXLAN in modern campus or data center networks? (Choose two.)
Correct Answer: A,C
Explanation: Only visible for Actualtests4sure members. You can sign-up / login (it's free).
Question 6
Manufacturing A.B.C. is an international, mid-sized company specializing in producing industrial equipment. They have been in the market for over two decades and have established themselves as a reputable player in their industry. However, due to rapid technological advancements, their current network infrastructure is outdated and struggling to keep up with the demands of modern manufacturing processes.
Manufacturing A.B.C.'s network is a mix of multi-vendor legacy wired and wireless components, causing frequent downtime and hampering their production efficiency. The aging equipment leads to slow data transfer rates, unreliable connectivity, and increased vulnerability to cyber threats.
Fiber Cabling should be also upgraded as mostly OM2 is being used.
Compounding the network issues, the recent departure of the CTO has left the company without a clear direction for the network refresh project. There is a lack of consensus among the management team regarding the scope, budget, and timeline for the upgrade.
The primary objectives of the manufacturing customer are as follows:
- Improve network performance and reliability to enhance production processes and minimize downtime
- Enhance network security to protect sensitive data and intellectual property
- Streamline communication and collaboration among different departments within the organization
- Ensure scalability to accommodate future growth and technology advancements Manufacturing A.B.C. seeks a comprehensive network refresh that includes the following components:
- Upgrading the wired infrastructure to high-speed Ethernet switches to support increased data transfer rates and reduce latency
- Implementing a robust wireless solution with enterprise-grade access points to provide seamless connectivity across the manufacturing facility
- Centralized network management tools to simplify administration and monitoring of the network Expectations:
The customer expects the network refresh project to be handled efficiently, with minimal disruption to their ongoing operations. They are looking for a reliable and experienced network solutions provider who can understand their unique manufacturing requirements and deliver a customized solution that aligns with their budget constraints. The manufacturing customer is keen on receiving clear project proposals and support in decision-making, given the recent change of the CTO.
Your role as a network solutions provider is to address their concerns, offer expert guidance, and present a well-defined plan to meet their objectives effectively.
Manufacturing A.B.C. needs to regulate various traffic types with QoS and the architect decided to use DWRR instead of SP queuing. Which switches support DWRR? (Choose two.)
Manufacturing A.B.C.'s network is a mix of multi-vendor legacy wired and wireless components, causing frequent downtime and hampering their production efficiency. The aging equipment leads to slow data transfer rates, unreliable connectivity, and increased vulnerability to cyber threats.
Fiber Cabling should be also upgraded as mostly OM2 is being used.
Compounding the network issues, the recent departure of the CTO has left the company without a clear direction for the network refresh project. There is a lack of consensus among the management team regarding the scope, budget, and timeline for the upgrade.
The primary objectives of the manufacturing customer are as follows:
- Improve network performance and reliability to enhance production processes and minimize downtime
- Enhance network security to protect sensitive data and intellectual property
- Streamline communication and collaboration among different departments within the organization
- Ensure scalability to accommodate future growth and technology advancements Manufacturing A.B.C. seeks a comprehensive network refresh that includes the following components:
- Upgrading the wired infrastructure to high-speed Ethernet switches to support increased data transfer rates and reduce latency
- Implementing a robust wireless solution with enterprise-grade access points to provide seamless connectivity across the manufacturing facility
- Centralized network management tools to simplify administration and monitoring of the network Expectations:
The customer expects the network refresh project to be handled efficiently, with minimal disruption to their ongoing operations. They are looking for a reliable and experienced network solutions provider who can understand their unique manufacturing requirements and deliver a customized solution that aligns with their budget constraints. The manufacturing customer is keen on receiving clear project proposals and support in decision-making, given the recent change of the CTO.
Your role as a network solutions provider is to address their concerns, offer expert guidance, and present a well-defined plan to meet their objectives effectively.
Manufacturing A.B.C. needs to regulate various traffic types with QoS and the architect decided to use DWRR instead of SP queuing. Which switches support DWRR? (Choose two.)
Correct Answer: A,D
Explanation: Only visible for Actualtests4sure members. You can sign-up / login (it's free).
Question 7
A global cruise line company needs to refresh its current fleet. They will refresh the 'insides' of the ship to be cost-effective and increase their sustainability. They will replace the complete WLAN/LAN hardware of the ship. In this refresh, the company will not refresh its current security requirements. The CIO also wants to limit the number of unused ports in the switches. Future expansion will always mean a refresh of hardware. They start with the smallest ship with a maximum of 800 guests.
Each ship has a LAN infrastructure consisting of two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins, 100 technical rooms). The Core switches are located in the MDF of the ship and the distribution switches are located in the IDFs of the ship. Each cabin and technical room gets one single access switch.
The cabling structure of the ship will not be refreshed. Each IDF is connected to the MDF by SMF, of which two pairs are available for the interconnect between the core and distribution. The length of SM fiber between MDF and IDF is less than 300 meters (980 ft) and the type used is OS1. Each cabin is connected by a single OM2 pair to the IDF, the maximum length is 60 meters (200 ft). Each technical room is connected by a single OM2 pair to the IDF, with lengths between
100 and 150 meters (320 and 500 ft).
For each cabin/technical room the customer is looking to replace their current fan-less 2530/2540 without changing the requirements, except they need to upgrade the uplink to distribution switch to 10GbE to handle the increased network traffic, and the technical rooms need redundant power.
The WLAN infrastructure will be 1:1 refreshed without new cabling or new AP locations. Their WLAN infrastructure is based on the 200/300 series indoor and outdoor APs running InstantOS (less than 300 APs), the customer has no change in WLAN requirements.
The cruise line company will replace its current Internet connection before the LAN/WLAN refresh. The new Internet connection will provide a 99.8% uptime, which is needed to ensure the paid guest Wi-Fi is always operational. With this new internet connection, the CIO of the cruise line wants to base the design on the ESP architecture from Aruba because Internet connection is guaranteed.
Based on HPE Aruba Networking best practices and the customer's stated requirements, which segmentation design approach is appropriate for this environment?
Each ship has a LAN infrastructure consisting of two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins, 100 technical rooms). The Core switches are located in the MDF of the ship and the distribution switches are located in the IDFs of the ship. Each cabin and technical room gets one single access switch.
The cabling structure of the ship will not be refreshed. Each IDF is connected to the MDF by SMF, of which two pairs are available for the interconnect between the core and distribution. The length of SM fiber between MDF and IDF is less than 300 meters (980 ft) and the type used is OS1. Each cabin is connected by a single OM2 pair to the IDF, the maximum length is 60 meters (200 ft). Each technical room is connected by a single OM2 pair to the IDF, with lengths between
100 and 150 meters (320 and 500 ft).
For each cabin/technical room the customer is looking to replace their current fan-less 2530/2540 without changing the requirements, except they need to upgrade the uplink to distribution switch to 10GbE to handle the increased network traffic, and the technical rooms need redundant power.
The WLAN infrastructure will be 1:1 refreshed without new cabling or new AP locations. Their WLAN infrastructure is based on the 200/300 series indoor and outdoor APs running InstantOS (less than 300 APs), the customer has no change in WLAN requirements.
The cruise line company will replace its current Internet connection before the LAN/WLAN refresh. The new Internet connection will provide a 99.8% uptime, which is needed to ensure the paid guest Wi-Fi is always operational. With this new internet connection, the CIO of the cruise line wants to base the design on the ESP architecture from Aruba because Internet connection is guaranteed.
Based on HPE Aruba Networking best practices and the customer's stated requirements, which segmentation design approach is appropriate for this environment?
Correct Answer: C
Explanation: Only visible for Actualtests4sure members. You can sign-up / login (it's free).
Question 8
As part of several technical proposals for a customer deploying both Wi-Fi 7 high-throughput HD and very high-throughput VHD networks based on HPE Aruba Networking AOS-10, you are outlining key considerations for radio frequency (RF) design and channel optimization.
Which statements represent recommended AOS-10 best practices for RF planning and should be included in your proposals to ensure optimal wireless performance? (Choose two.)
Which statements represent recommended AOS-10 best practices for RF planning and should be included in your proposals to ensure optimal wireless performance? (Choose two.)
Correct Answer: A,C
Explanation: Only visible for Actualtests4sure members. You can sign-up / login (it's free).
Question 9
A large multinational financial institution has contracted you to design a new full-stack wired and wireless network for their new 6-story regional office building. The bottom two floors of this facility will be retail space for a large banking branch. The upper floors will be carpeted office space for corporate users, each floor being approximately 100,000 sq ft (9290 sq m). Data centers are all offsite and will be out of scope for this project. The customer is underserved by its existing L2- based network infrastructure and would like to take advantage of modern best practices in the new design. The network should be fully resilient and fault-tolerant, with dynamic segmentation at the edge.
The retail space will include public guest Wi-Fi access. Retail associates will have corporate tablets for customer service, and there will be a mix of wired and wireless devices throughout the retail floors. The corporate users will primarily use wireless for connectivity, but several wired clients, printers, and hard VoIP phones will be in use.
The customer is also planning on renovating the corporate office space in order to take advantage of 'smart office' technology. These improvements will drive blue-dot wayfinding, presence analytics, and other location-based services.
Through additional conversations with the customer, the team has determined that they will use EVPN-VXLAN to deliver dynamic segmentation. The customer wants to ensure that a particular VNI is only present when it is in use on that switch.
Which solution is valid and satisfies this technical requirement?
The retail space will include public guest Wi-Fi access. Retail associates will have corporate tablets for customer service, and there will be a mix of wired and wireless devices throughout the retail floors. The corporate users will primarily use wireless for connectivity, but several wired clients, printers, and hard VoIP phones will be in use.
The customer is also planning on renovating the corporate office space in order to take advantage of 'smart office' technology. These improvements will drive blue-dot wayfinding, presence analytics, and other location-based services.
Through additional conversations with the customer, the team has determined that they will use EVPN-VXLAN to deliver dynamic segmentation. The customer wants to ensure that a particular VNI is only present when it is in use on that switch.
Which solution is valid and satisfies this technical requirement?
Correct Answer: C
Explanation: Only visible for Actualtests4sure members. You can sign-up / login (it's free).
Question 10
Drag and Drop Question
Match the deployment type to the estimated number of APs.

Match the deployment type to the estimated number of APs.

Correct Answer:

Question 11
A global cruise line company needs to refresh its current fleet. They will refresh the 'insides' of the ship to be cost-effective and increase their sustainability. They will replace the complete WLAN/LAN hardware of the ship. In this refresh, the company will not refresh its current security requirements. The CIO also wants to limit the number of unused ports in the switches. Future expansion will always mean a refresh of hardware. They start with the smallest ship with a maximum of 800 guests.
Each ship has a LAN infrastructure consisting of two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins, 100 technical rooms). The Core switches are located in the MDF of the ship and the distribution switches are located in the IDFs of the ship. Each cabin and technical room gets one single access switch.
The cabling structure of the ship will not be refreshed. Each IDF is connected to the MDF by SMF, of which two pairs are available for the interconnect between the core and distribution. The length of SM fiber between MDF and IDF is less than 300 meters (980 ft) and the type used is OS1. Each cabin is connected by a single OM2 pair to the IDF, the maximum length is 60 meters (200 ft). Each technical room is connected by a single OM2 pair to the IDF, with lengths between
100 and 150 meters (320 and 500 ft).
For each cabin/technical room the customer is looking to replace their current fan-less 2530/2540 without changing the requirements, except they need to upgrade the uplink to distribution switch to 10GbE to handle the increased network traffic, and the technical rooms need redundant power.
The WLAN infrastructure will be 1:1 refreshed without new cabling or new AP locations. Their WLAN infrastructure is based on the 200/300 series indoor and outdoor APs running InstantOS (less than 300 APs), the customer has no change in WLAN requirements.
The cruise line company will replace its current internet connection before the LAN/WLAN refresh. The new Internet connection will provide a 99.8% uptime, which is needed to ensure the paid quest Wi-Fi is always operational. With this new Internet connection, the CIO of the cruise line wants to base the design on the ESP architecture from Aruba because internet connection is guaranteed.
Based on the best practices, what should be recommended as the most cost-effective switch model for the technical rooms?
Each ship has a LAN infrastructure consisting of two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins, 100 technical rooms). The Core switches are located in the MDF of the ship and the distribution switches are located in the IDFs of the ship. Each cabin and technical room gets one single access switch.
The cabling structure of the ship will not be refreshed. Each IDF is connected to the MDF by SMF, of which two pairs are available for the interconnect between the core and distribution. The length of SM fiber between MDF and IDF is less than 300 meters (980 ft) and the type used is OS1. Each cabin is connected by a single OM2 pair to the IDF, the maximum length is 60 meters (200 ft). Each technical room is connected by a single OM2 pair to the IDF, with lengths between
100 and 150 meters (320 and 500 ft).
For each cabin/technical room the customer is looking to replace their current fan-less 2530/2540 without changing the requirements, except they need to upgrade the uplink to distribution switch to 10GbE to handle the increased network traffic, and the technical rooms need redundant power.
The WLAN infrastructure will be 1:1 refreshed without new cabling or new AP locations. Their WLAN infrastructure is based on the 200/300 series indoor and outdoor APs running InstantOS (less than 300 APs), the customer has no change in WLAN requirements.
The cruise line company will replace its current internet connection before the LAN/WLAN refresh. The new Internet connection will provide a 99.8% uptime, which is needed to ensure the paid quest Wi-Fi is always operational. With this new Internet connection, the CIO of the cruise line wants to base the design on the ESP architecture from Aruba because internet connection is guaranteed.
Based on the best practices, what should be recommended as the most cost-effective switch model for the technical rooms?
Correct Answer: B
Explanation: Only visible for Actualtests4sure members. You can sign-up / login (it's free).
Question 12
A global cruise line company needs to refresh its current fleet. They will refresh the 'insides' of the ship to be cost-effective and increase their sustainability. They will replace the complete WLAN/LAN hardware of the ship. In this refresh, the company will not refresh its current security requirements. The CIO also wants to limit the number of unused ports in the switches. Future expansion will always mean a refresh of hardware. They start with the smallest ship with a maximum of 800 guests.
Each ship has a LAN infrastructure consisting of two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins, 100 technical rooms). The Core switches are located in the MDF of the ship and the distribution switches are located in the IDFs of the ship. Each cabin and technical room gets one single access switch.
The cabling structure of the ship will not be refreshed. Each IDF is connected to the MDF by SMF, of which two pairs are available for the interconnect between the core and distribution. The length of SM fiber between MDF and IDF is less than 300 meters (980 ft) and the type used is OS1. Each cabin is connected by a single OM2 pair to the IDF, the maximum length is 60 meters (200 ft). Each technical room is connected by a single OM2 pair to the IDF, with lengths between
100 and 150 meters (320 and 500 ft).
For each cabin/technical room the customer is looking to replace their current fan-less 2530/2540 without changing the requirements, except they need to upgrade the uplink to distribution switch to 10GbE to handle the increased network traffic, and the technical rooms need redundant power.
The WLAN infrastructure will be 1:1 refreshed without new cabling or new AP locations. Their WLAN infrastructure is based on the 200/300 series indoor and outdoor APs running InstantOS (less than 300 APs), the customer has no change in WLAN requirements.
The cruise line company will replace its current Internet connection before the LAN/WLAN refresh. The new Internet connection will provide a 99.8% uptime, which is needed to ensure the paid guest Wi-Fi is always operational. With this new internet connection, the CIO of the cruise line wants to base the design on the ESP architecture from Aruba because Internet connection is guaranteed.
Based on the best practices, what is the most cost-effective switch model for the distribution?
Each ship has a LAN infrastructure consisting of two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins, 100 technical rooms). The Core switches are located in the MDF of the ship and the distribution switches are located in the IDFs of the ship. Each cabin and technical room gets one single access switch.
The cabling structure of the ship will not be refreshed. Each IDF is connected to the MDF by SMF, of which two pairs are available for the interconnect between the core and distribution. The length of SM fiber between MDF and IDF is less than 300 meters (980 ft) and the type used is OS1. Each cabin is connected by a single OM2 pair to the IDF, the maximum length is 60 meters (200 ft). Each technical room is connected by a single OM2 pair to the IDF, with lengths between
100 and 150 meters (320 and 500 ft).
For each cabin/technical room the customer is looking to replace their current fan-less 2530/2540 without changing the requirements, except they need to upgrade the uplink to distribution switch to 10GbE to handle the increased network traffic, and the technical rooms need redundant power.
The WLAN infrastructure will be 1:1 refreshed without new cabling or new AP locations. Their WLAN infrastructure is based on the 200/300 series indoor and outdoor APs running InstantOS (less than 300 APs), the customer has no change in WLAN requirements.
The cruise line company will replace its current Internet connection before the LAN/WLAN refresh. The new Internet connection will provide a 99.8% uptime, which is needed to ensure the paid guest Wi-Fi is always operational. With this new internet connection, the CIO of the cruise line wants to base the design on the ESP architecture from Aruba because Internet connection is guaranteed.
Based on the best practices, what is the most cost-effective switch model for the distribution?
Correct Answer: A
Explanation: Only visible for Actualtests4sure members. You can sign-up / login (it's free).
Question 13
Before beginning the design for HPE Aruba Networking Cloud Authentication at a distributed enterprise, you must gather information about the customer's existing identity infrastructure and endpoint capabilities. The customer has expressed interest in a cloud-native authentication solution, but you have to gather details about their identity infrastructure or endpoint capabilities.
As the network architect, you need to move forward with initial planning by documenting reasonable assumptions about their current environment and their readiness to support cloud- native authentication.
Which assumptions would be appropriate to include at this stage to guide your design process?
(Choose two.)
As the network architect, you need to move forward with initial planning by documenting reasonable assumptions about their current environment and their readiness to support cloud- native authentication.
Which assumptions would be appropriate to include at this stage to guide your design process?
(Choose two.)
Correct Answer: C,D
Explanation: Only visible for Actualtests4sure members. You can sign-up / login (it's free).