NEW QUESTION 30
What does a Storage Administrator need to consider about Resource Balance when assigning volumes?

  • A. Whether the Node is offline Appliance failure status Node utilization
  • B. Whether the appliance is online Appliance failure status
    Cluster utilization
  • C. Whether the Cluster is offline Node failure status
    I/O utilization
  • D. Whether the appliance is offline Appliance failure status Capacity utilization

Answer: D

 

NEW QUESTION 31
A PowerStore X system is being implemented using Dell EMC S5248F-ON Ethernet switching as data switches.
What is required when configuring the VLT interconnects on the data switches?

  • A. Set the VLT connection to the switch default VLAN
  • B. Configure the VLT MACs with a matching unique made-up address
  • C. Assign the switch default route for the VLT traffic
  • D. On each switch, select the switch management port MAC as the VLT MAC

Answer: D

 

NEW QUESTION 32
An administrator has performed the Cutover operation for an import session from a VNX2 source storage system.
What is a result of the operation?

  • A. Host is removed from the VNX2 Storage Group
  • B. Imported LUN is removed from the VNX2 Storage Group
  • C. Imported LUN is deleted from the VNX2
  • D. Storage Group containing the imported LUN is deleted

Answer: B

Explanation:
Reference: https://laptrinhx.com/what-is-dell-emc-powerstore-part-7-importing-external-storage-146661351/

 

NEW QUESTION 33
What is the total number of NVRAM devices used in PowerStore 3000?

  • A. 0
  • B. 1
  • C. Up to 21
  • D. Up to 6

Answer: B

 

NEW QUESTION 34
Refer to the Exhibit.

A Network administrator is failing to discover a PowerStore T system using the PowerStore Discovery Utility. What might be the issue?

  • A. Dedicated port needs to be used for discovery network
  • B. Discovery network uses only native VLAN
  • C. Port 54 has not been set to trunk mode
  • D. Port 54 needs to be enabled

Answer: A

 

NEW QUESTION 35
An administrator received the following alert from PowerStore regarding a previously created NAS server?
Description:
The SMB server of the NAS server PowerStore_NAS_01 is configured to be joined to the domain test.mid, but is currently not joined.
Which setting should the administrator change?

  • A. SMB
  • B. NTP
  • C. UDS
  • D. LDAP

Answer: A

 

NEW QUESTION 36
How is the VASA provider registered with vSphere when connecting to a PowerStore X system?

  • A. Built into the PowerStore X system code
  • B. Automatically added during Initial Configuration
  • C. Manually added from vCenter server using add storage provider option
  • D. VASA is unsupported in PowerStore X models

Answer: B

Explanation:
Reference:
https://www.delltechnologies.com/en-ca/collaterals/unauth/white-papers/products/storage/h18116- dell-emc-powerstore-vmware-vsphere-best-practices.pdf (17)

 

NEW QUESTION 37
Use the PowerStore Manager simulator to configure the BaseEnclosure-NodeA-IoModule1-FEport0 as a replication port. When you have finished using the simulator, Click Next.

Answer:

Explanation:
check the answer below in explanation.
Explanation
Below are the exhibits solution for this simulation.








 

NEW QUESTION 38
You are a network administrator that needs to setup a Data switch model S5248F-ON to be used for PowerStore 7000T system Use the Simulator to:
1) Check the OS version and license status.
2) Set management IP address 172.17.57.10 subnet as 255.255.255.0 on chassis = 1, slot = 1, port = 10
3) Enable the port
4) Configure default route with gateway 192.168.1.254, NTP server 192.168.1.50
5) Enable RSTP with priority 4096
6) Commit and exit.

Answer:

Explanation:
Below are the exhibits solution for this simulation.

 

NEW QUESTION 39
When planning rack layout, why should base enclosures be grouped together?

  • A. Power distribution requirements
  • B. Ease of cable management
  • C. Hot aisle requirement
  • D. Rack weight balance

Answer: B

 

NEW QUESTION 40
Refer to the Exhibit.

What happens to the parent resource of thin clone 3 if thin clone 2 is deleted?

  • A. Thin clone 3 becomes parent
  • B. Snapshot 3 becomes the parent
  • C. Thin clone 1 becomes parent
  • D. Thin clone 3 has an empty parent

Answer: D

 

NEW QUESTION 41
What does the remote replication Failover operation do?

  • A. Promotes the destination system to production with its replica data consistent to the last successful RPO synchronization state
  • B. Fully synchronizes the source and destination data states and reverses the replication direction
  • C. Promotes the destination system to production and resets the RPO synchronization cycle in the protection policy
  • D. Fully synchronizes the source and destination data states and stops the current replication session

Answer: A

 

NEW QUESTION 42
An administrator receives an alert on a PowerStore Cluster with three appliances:
The appliance A1 is projected to run out of space in 8 days
Capacity utilization is above 90 percent
Which tools are available to assist the Administrator with a potential resolution?

  • A. Assisted Migration
  • B. Thin provision conversion wizard
  • C. System Optimization
  • D. Space reclamation wizard

Answer: A

Explanation:
Explanation/Reference:
Reference: https://volumes.blog/2020/05/18/what-is-powerstore-part-11-resource-balancer/

 

NEW QUESTION 43
Which API does PowerStore use to communicate with ESXi server during vVols provisioning operation?

  • A. VASA
  • B. REST
  • C. SOAP
  • D. VAAI

Answer: A

 

NEW QUESTION 44
What does the data import session Pause operation do?

  • A. Stops the source to PowerStore cutover operation
  • B. Deactivates the host to PowerStore control path
  • C. Deactivates the host to PowerStore data path
  • D. Stops the source to PowerStore background copy operation

Answer: D

 

NEW QUESTION 45
1.a.1 What is the maximum number of appliances that can be connected to form a cluster?

  • A. 1 in a PowerStore T cluster, 1 in a PowerStore X cluster
  • B. 4 in a PowerStore T cluster, 1 in a PowerStore X cluster
  • C. 1 in a PowerStore T cluster, 4 in a PowerStore X cluster
  • D. 4 in a PowerStore T cluster, 4 in a PowerStore X cluster

Answer: B

 

NEW QUESTION 46
Match the CLI command to the appropriate configuration.

Answer:

Explanation:

 

NEW QUESTION 47
While configuring a Dell switch with PowerStore, what are the recommended license outputs from a show license status command?

  • A. Type: Perpetual, Status: Active
  • B. Type: Term-Based, Status: Active
  • C. Status: Perpetual, Type: Open
  • D. Status: Term-Based, Type: Unlimited

Answer: A

 

NEW QUESTION 48
What describes the process used in the Import External Storage migration architecture?

  • A. Plugin on PowerStore communicates over the control path to orchestrator on the host and controls the multipathing active path to storage
  • B. Orchestrator on PowerStore communicates over the control path to the host plugin and controls the multipathing active path to storage
  • C. Plugin on PowerStore communicates over the data path to orchestrator on the host and controls the multipathing active path to storage
  • D. Orchestrator on PowerStore communicates over the data path to the host plugin and controls the multipathing active path to storage

Answer: C

Explanation:
Reference: https://www.dell.com/support/manuals/en-pk/powerstore-1000/pwrstr-import/importing-external- storage-to-powerstore-overview?guid=guid-6fef77c4-d4c9-49c6-8de2-efd67aa52ca5

 

NEW QUESTION 49
Which administrator tasks are needed to increase the size of a VMFS datastore without the use of the VSI plugin, mounted to an external ESXi host?

  • A. Change the volume size in PowerStore Manager and refresh the size of the datastore in vSphere
  • B. Change the size of the datastore in vSphere and restart the VAAI service in PowerStore Manager
  • C. Change the volume size in PowerStore Manager and restart the VASA service in vSphere
  • D. Change the size of the datastore in vSphere and refresh the size of the volume in PowerStore Manager

Answer: A

Explanation:
Reference:
https://www.delltechnologies.com/en-us/collaterals/unauth/white-papers/products/storage/h18116- dell-emc-powerstore-vmware-vsphere-best-practices.pdf

 

NEW QUESTION 50
Refer to the Exhibit.

Note the yellow arrow. A Data Center Engineer notices that the LED is blinking blue and amber alternating at one second intervals. What does this indicate?

  • A. System is booting
  • B. System not initialized
  • C. Node is Degraded
  • D. Node in Service Mode

Answer: D

 

NEW QUESTION 51
How many cables are required for minimum support for PowerStore T Front-End storage connectivity?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

Explanation:
Explanation

 

NEW QUESTION 52
Refer to the Exhibit.

Note the yellow arrow. A Data Center Engineer notices that the LED is blinking blue and amber alternating at one second intervals. What does this indicate?

  • A. System is booting
  • B. System not initialized
  • C. Node is Degraded
  • D. Node in Service Mode

Answer: D

Explanation:
Reference: https://www.dell.com/support/manuals/en-pk/powerstore/pwrstr-isg/embedded-module-leds?
guid=guid-bc07892c-75cf-43b6-8f17-8a4c49001aeb&lang=en-us

 

NEW QUESTION 53
......


Understanding functional and technical aspects of Specialist - Implementation Engineer, PowerStore Solutions Version 1.0 PowerStore Implementation (18%)

The following will be discussed in DELL DES-1221 exam dumps pdf:

  • Perform PowerStore installation planning
  • Discover and perform initial system configuration of PowerStore
  • Describe and perform licensing process for PowerStore
  • Configure Ethernet switching for PowerStore
  • Rack and stack PowerStore systems

 

Specialist - Implementation Engineer, PowerStore Solutions Exam Free Update Certification Sample Questions: https://www.actualtests4sure.com/DES-1221-test-questions.html

Trend for EMC DES-1221 pdf dumps before actual exam: https://drive.google.com/open?id=1jwFsB7oKqckRnHRPwwgayb8bwe99QcvG