[Q11-Q36] 100% Free NS0-516 Exam Dumps Use Real NCIE SAN E-Series Dumps With 66 Questions!

Share

100% Free NS0-516 Exam Dumps Use Real NCIE SAN E-Series Dumps With 66 Questions!

Pass Your NS0-516 Exam Easily With 100% Exam Passing Guarantee [2024]


Network Appliance NS0-516 (NetApp Implementation Engineer SAN Specialist E-Series (NCIE)) Certification Exam is designed for IT professionals who specialize in deploying and managing NetApp E-Series storage systems. NetApp Implementation Engineer SAN Specialist E-Series (NCIE) certification validates the skills and knowledge required to implement, configure, and manage E-Series storage solutions in complex multiprotocol environments.


Network Appliance NS0-516 Certification Exam is designed for professionals who want to validate their skills in designing, deploying, and managing NetApp E-Series SAN solutions. NS0-516 exam focuses on SAN design, protocols, installation, troubleshooting, and optimization. NetApp Implementation Engineer SAN Specialist E-Series (NCIE) certification is intended for individuals who have already achieved the NetApp Certified Data Administrator (NCDA) credential and want to specialize their knowledge in the area of E-Series SAN.

 

NEW QUESTION # 11
When a drive fails in a Dynamic Disk Pool (DDP) with no free capacity, what happens to the data?

  • A. It is evacuated to a hot spare drive that is assigned to the DDP
  • B. It is evacuated to the preservation capacity within the DDP
  • C. It is rebuilt using preservation capacity within the DDP
  • D. It is rebuilt using the on-board backup database

Answer: C


NEW QUESTION # 12
What is SMutil? (Choose the best answer.)

  • A. an OS-dependent collection of utilities for servers attached to SANtricity-managed storage systems
  • B. inter-process communication that supports computer program subroutines
  • C. a host server process that enables storage system management with the storage data path
  • D. a host I/O performance modeling interface
  • E. a GUI or CLI run on a host server used for storage system management

Answer: A


NEW QUESTION # 13
When data is written to a snapshot, volume is stored __________. (Choose the best answer.)

  • A. on the repository associated with the snapshot volume
  • B. on the repository area associated with the snapshot's corresponding image
  • C. on the base volume for that snapshot
  • D. on a hot spare drive
  • E. on the common repository for the snapshot group

Answer: E


NEW QUESTION # 14
What is the proper order to power-on E-Series arrays when a storage system has at least 2 trays? (Choose the best answer.)

  • A. Power on the controller drive tray first, then wait several minutes for the controller drive tray to spin up, and then power on all expansion drive trays
  • B. Power on in any order, since the order does not matter
  • C. Power all expansion drive trays first, wait several minutes for the expansion drive trays to spin up, and then power on the controller drive tray
  • D. Power up A-side power supplies first, then power up all B-side power supplies.

Answer: A


NEW QUESTION # 15
Exhibit:

Referring to the exhibit, which cable is an InfiniBand 4X connector?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A


NEW QUESTION # 16
Which three documents should be provided to the customer after the e-Series installation is complete?
(choose three.)

  • A. a document showing available power on the UPS with no equipment connected
  • B. a b a document with IMT pages that show the supported host configuration and fabric switches in the solution
  • C. a document showing how much space is available for system expansion
  • D. a document showing user IDs and passwords for all deployed devices
  • E. a document showing the cabinet layout with cabling information and IP addresses being used

Answer: B,D,E


NEW QUESTION # 17
Which SANtricity client utility associates a LUN with a host OS storage system device?

  • A. SMrepassist
  • B. SMdevices
  • C. SANLUN
  • D. SANsurfer

Answer: B


NEW QUESTION # 18
An administrator is asked to provision a 1 TB volume to hold non-critical temporary data for a seismic-analysis application. The volume requires the highest possible IOPS.
In this scenario, which configuration would satisfy this requirement?

  • A. RAID 0 volume group with a 32 KiB segment size
  • B. RAID 6 Dynamic Disk Pool with a 256 KiB segment size
  • C. RAID 5 volume group with a 256 KiB segment size
  • D. RAID 6 Dynamic Disk Pool with a 32 KiB segment size

Answer: C


NEW QUESTION # 19
Click the Exhibit button.

A customer has a raised floor with a weight limit of 700 lb. per floor tile. The customer's data cabinet weights
90 lb. and covers a single floor tile.
Referring to the exhibit, what is the maximum number of E2824 shelves possible to be installed?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

Explanation:
* Total weight capacity per tile: 700 lb.
* Data cabinet weight: 90 lb.
* Available weight for shelves: 700 lb. - 90 lb. = 610 lb.
* Weight of an E2824 shelf (maximum): 60.5 lb.
* Number of shelves: 610 lb. / 60.5 lb. 10 shelves
* However, considering the safety margin and not exceeding the weight limit, we take 6 shelves as a practical maximum.
* References: Weight table for E2824 controller shelf and EF280 flash array.


NEW QUESTION # 20
Click the Exhibit button.

An administrator is asked to create a 5532 GiB volume from the volume group.
Referring to the exhibit, how would the administrator complete this request?

  • A. Create the volume after consolidating the capacity
  • B. Create the volume from the available capacity
  • C. Create the volume after performing space reclamation
  • D. Create the volume after adjusting the preservation capacity

Answer: A

Explanation:
* Review the Available Capacity:According to the exhibit, the volume group has a total of 17820.00 GiB capacity, out of which 5532.00 GiB is the current free capacity. However, it is split into two free capacity areas of 15120.00 GiB and 2412.00 GiB.
* Identify the Challenge:The requested volume of 5532 GiB cannot be created directly from the current
* free capacity because it is not contiguous; it's split into two separate areas.
* Consolidate the Capacity:To create the volume, the administrator needs to consolidate the free capacity. This involves merging the non-contiguous free spaces to form a contiguous space large enough for the 5532 GiB volume.
* Procedure for Consolidation:
* Access the volume group management settings.
* Select the option to consolidate free capacity areas.
* Follow the prompts to merge the two free capacity areas into a single contiguous space.
* Create the Volume:Once the free capacity is consolidated, proceed to create the 5532 GiB volume from the newly formed contiguous free space.


NEW QUESTION # 21
A customer is experiencing performance issues on their NetApp E-Series system that is running with iSCSI host interface cards (HICs).
In this scenario, in which two locations in the GUI would you go to find detailed statistics for the ISCSI connections on this system? (Choose two.)

  • A. Support -> Support Resources -> Storage Array Profile
  • B. Support -> Support Center -> Diagnostics -> View iSCSI Statistics
  • C. Home -> View Performance Details
  • D. Settings -> System -> View ISCSI Statistics

Answer: B,D


NEW QUESTION # 22
Which three documents should be provided to the customer after the E-Series installation is complete?
(Choose three.)

  • A. a document with IMT pages that show the supported host configuration and fabric switches in the solution
  • B. a document showing how much space is available for system expansion
  • C. a document showing user IDs and passwords for all deployed devices
  • D. a document showing the cabinet layout with cabling information and IP addresses being used
  • E. a document showing available power on the UPS with no equipment connected

Answer: C,D,E


NEW QUESTION # 23
Storage system volumes can be built upon what two types of logical structures? (Choose the best answer.)

  • A. Volume Pools and Virtual Disks
  • B. Virtual Disks and Disk Pools
  • C. Volume Groups and Disk Pools
  • D. Volume Pools and Volume Groups
  • E. Volume Groups and Virtual Disks

Answer: C


NEW QUESTION # 24
Click the Exhibit button.

You ordered a NetApp E2812 Duplex 16GB 10 GbE Base-T system.
Referring to the exhibit, what is the maximum number of 10GbE Base-T ports available to be used?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D


NEW QUESTION # 25
According to NetApp recommended practices, is this E2712 storage system cabled for a dual-stack configuration? If not, why?

  • A. No. The cabling to the disk shelves is coming from the host ports.
  • B. No. The controllers are only cabled to one "stack."
  • C. No. The cabling has split the top-down-bottom-up configuration.
  • D. Yes. The cabling configuration is correct.

Answer: D


NEW QUESTION # 26
You are adding drives to an existing Dynamic Disk Pool (DDP). In this scenario, which two drive characteristics should you consider when selecting the drives? (Choose two.)

  • A. if the drives have a compatible security type
  • B. if the drives have the same firmware level
  • C. if the drives are from the same manufacturer
  • D. if the drives are the same capacity or larger

Answer: A,D


NEW QUESTION # 27
A host is unable to access volumes as shown in the exhibit.

Which statement is correct in this scenario?

  • A. A workload has not been added in SANtricity System Manager.
  • B. A host has not been added in SANtricity System Manager.
  • C. A pool has not been added in SANtricity System Manager.
  • D. A volume has not been added in SANtricity System Manager.

Answer: B


NEW QUESTION # 28
Which two actions must be performed to enable iSCSI multipathing on Windows for NetApp E-Series systems? (Choose two.)

  • A. Create two VSANs on the iSCSI switches
  • B. Install the Host Utilities on the Windows host
  • C. Set up iSCSI IP addresses on the E-Series system and the Windows host
  • D. Install a Host Channel Adapter (HCA) on the Windows host

Answer: B,C


NEW QUESTION # 29
An E2812 system, without expansion shelves, is configured with 12 Gb SAS host interface cards (HICs) and is directly connected to a host. However, the host cannot access the volumes.
In this scenario, which two troubleshooting steps should you take? (Choose two.)

  • A. Verify that the host can ping the E2812 system over the SAS link
  • B. Verify that the correct SAS ports are in use on the E2812 system
  • C. Verify that the E2812 SAS CHAP secret is set
  • D. Verify that the E2812 host port SAS link up lights are illuminated

Answer: B,D

Explanation:
Verify that the E2812 host port SAS link up lights are illuminated
* Explanation: The link up lights on the E2812 host port should be checked to confirm that the physical layer connection is established. If the lights are not illuminated, it indicates that there is no physical link between the host and the E2812 system, which would explain why the host cannot access the volumes.


NEW QUESTION # 30
A junior administrator recently made changes to an E-Series system. As a result of these changes, the management host lost the ability to manage the E-Series system through in-band management, but the host still has access to the E-Series data volumes.
In this scenario, what caused this issue?

  • A. Auto Load Balancing was disabled
  • B. The ownership of the management host's volumes changed
  • C. The access volume was un-mapped
  • D. The management IPs were changed

Answer: D


NEW QUESTION # 31
An E-Series customer can find out when a specific volume was deleted by using the ______. (Choose the best answer.)

  • A. Online Help
  • B. Recovery Guru
  • C. Storage Array Profile
  • D. Major Event Log

Answer: B


NEW QUESTION # 32
What are two methods for setting the host protocol configuration on the E2800 controller with a 4-port 16Gbps FC or 10Gbps iSCSI SFP+ host interface card (HIC)? (Choose two)

  • A. Change the feature pack in the SANtricity System Manager.
  • B. Set in the hardware tab using SANtricity System Manager
  • C. Change the QSFP type in the HIC
  • D. Set at the factory based on the order.

Answer: A,C


NEW QUESTION # 33
During normal operation, a failure was detected on an E-Series hardware component. You want to determine the location of the failed component and understand the potential recovery actions.
In this scenario, which tool would you use to accomplish this task?

  • A. unreadable sectors log
  • B. performance monitor
  • C. Recovery Guru
  • D. Host Mappings tab

Answer: C


NEW QUESTION # 34
The Netapp E-Series system with a 32 Gb FC Host Interface Card (HIC) requires which type of fiber cable to connect to switches or to connect directly to hosts extending up to 100 meters?

  • A. OM4
  • B. OM1
  • C. OM2
  • D. OM3

Answer: D


NEW QUESTION # 35
How many 32 Gb ports are on one FC host interface card (HIC) on the NetApp E2800, EF280, E5700, and EF570 systems?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 36
......


Successful candidates who pass the NS0-516 exam are able to demonstrate their ability to design and implement NetApp E-Series SAN solutions that meet the requirements of their organizations. They are also able to troubleshoot and resolve issues that may arise in these environments, as well as manage and optimize the performance of the storage infrastructure.

 

Study resources for the Valid NS0-516 Braindumps: https://www.actualtests4sure.com/NS0-516-test-questions.html