NACE-CIP1-001 Exam PDF [2024] Tests Free Updated Today with Correct 100 Questions [Q42-Q60]

Share

NACE-CIP1-001 Exam PDF [2024] Tests Free Updated Today with Correct 100 Questions

NACE NACE-CIP1-001 Exam Preparation Guide and PDF Download

NEW QUESTION # 42
Which one of the following documents is the best source for coating technical data:

  • A. Technical Data Sheet
  • B. Specification
  • C. Application Guidelines
  • D. Safety Data Sheet;

Answer: A


NEW QUESTION # 43
In the event of a conflict between the project specification and the coating manufactures' product data sheet, the Inspector's first course of action should be too:

  • A. Call the coating manufacturer for clarification
  • B. Use the product data sheet as a guide
  • C. Call the person who wrote the specification for clarification
  • D. Use the job specification as a guide

Answer: D


NEW QUESTION # 44
A magnetic pull-off type gauge is a good choice when:

  • A. Accuracy is not required
  • B. Performing an adhesion test
  • C. When an intrinsically safe tool is required
  • D. When working on non-ferrous metals

Answer: C


NEW QUESTION # 45
Checking is

  • A. a fine crack in the surface of a coating that rarely reaches the substrate
  • B. surface breaks in the film that often result from grease or oil contamination and revel the substrate.
  • C. an exposed area of the substrate or previous coat material, caused by poor application technique.
  • D. a very small hole in a coating caused when air or solvent is trapped in porous film and then escapes.

Answer: A


NEW QUESTION # 46
Whenever dissimilar metals must join, the most common practice is to

  • A. coat all connected dissimilar metals.
  • B. provide anodic protection to prevent corrosion.
  • C. avoid coating all connected dissimilar metals.
  • D. provide cathodic protection to prevent corrosion,

Answer: A


NEW QUESTION # 47
To achieve consistently accurate results with ALL alt test equipment

  • A. calibrate the instrument in the field.
  • B. wash your hands before sampling.
  • C. avoid placing the sample discs on a surface.
  • D. wear gloves when sampling.

Answer: B


NEW QUESTION # 48
If the specifier does not identify a restriction level in accordance with SSPC PA 2, the default restriction level is:

  • A. Level 1
  • B. Level 2
  • C. Level 3
  • D. Level 4

Answer: C


NEW QUESTION # 49
ISO SA 2.5 is defined as:

  • A. Light Blast Cleaning
  • B. Very Thorough Blast Cleaning
  • C. Thorough Blast Cleaning
  • D. Near White Metal Blasting

Answer: B


NEW QUESTION # 50
Most industrial coatings are:

  • A. Inorganic
  • B. Organic
  • C. Resistant to concentrated sulfuric acid
  • D. Resistant to temperatures above 200C

Answer: B


NEW QUESTION # 51
NACE Level 1 Inspectors have been trained to perform:

  • A. Visual inspection only
  • B. All types of inspection
  • C. Visual inspection and Non-destructive testing
  • D. Visual inspection, Non-Destructive and Destructive testing

Answer: C


NEW QUESTION # 52
The Inspector's Log Book is generally:

  • A. Shared with all parties upon project completion
  • B. Submitted to the client upon project completion
  • C. Retained by the inspector upon project completion
  • D. Shredded by the inspector upon project completion

Answer: C


NEW QUESTION # 53
Passivation can best be described as:

  • A. Complete elimination pf the corrosion process
  • B. A coating layer applied to the surface to inhibit corrosion
  • C. Treating metal with a liquid inhibiter
  • D. A protective metallic oxide surface layer that slows corrosion

Answer: D


NEW QUESTION # 54
You are an inspector on a project where SSPC SP 3 is specified.
What sort of tools should you expect the Contractor to use to achieve the standard?

  • A. Hand tools
  • B. Airless spray equipment
  • C. Abrasive blast nozzles
  • D. Power tools

Answer: D


NEW QUESTION # 55
If the project specification DOES NOT state the specific DFT measurement standards, the inspector should use

  • A. NACE 2/SSPC SP10
  • B. a detailed checklist and document the lack of a standard.
  • C. their best judgment based on similar projects and specifications.
  • D. a recognized industry standard like SSPC-PA 2 that is broadly accepted

Answer: D


NEW QUESTION # 56
ISO SA 3 is directly equivalent to:

  • A. NACE No. 2/SSPC SP 10
  • B. NACE No. 1/SSPC SP 5
  • C. NACE No. 3/SSPC SP 6
  • D. None of the above

Answer: D


NEW QUESTION # 57
How many gauge readings does SSPC-PA 2 require within a 4 cm (1.5 inch) diameter circle?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 58
An exposed area of the substrate or previous coat of a conductive coating material, often caused by poor application technique is called

  • A. sagging.
  • B. holiday.
  • C. checking.
  • D. cracking.

Answer: B


NEW QUESTION # 59
A successful coating inspector must be able to

  • A. apply the coating with expert accuracy.
  • B. advise the coating applicator on how to mix the coating.
  • C. look for problems or issues during application.
  • D. recommend the appropriate coating technique for the job to the contractor.

Answer: C


NEW QUESTION # 60
......

Verified & Correct NACE-CIP1-001 Practice Test Reliable Source Oct 19, 2024 Updated: https://www.actualtests4sure.com/NACE-CIP1-001-test-questions.html

Free NACE NACE-CIP1-001 Exam Files Downloaded Instantly: https://drive.google.com/open?id=1iXP0ROGNHQe_jO1x6KsdXbg_Nt-rDdXP